Range of application
Serious Glass Sheet Level Gauge is a kind of sight glass level gauge which can show the liquid level directly. These type level gauges are widely used in chemical industries and petroleum field.
1.Technique Parameters:
2.Model selection
When open the packing, firstly check the substance, and tight the bolt again. And then according to the picture equip with the accessories.
3. Installation
Serious Glass Sheet Level Gauge is a kind of sight glass level gauge which can show the liquid level directly. These type level gauges are widely used in chemical industries and petroleum field.
1.Technique Parameters:
Glass type | borosilicate glass, mica glass/Al-Si glass |
Gasket material | graphite gasket, mica gasket |
Pressure for steel ball shut off automatically | More than 0.2Mpa |
Steam pressure less than 0.6Mpa | Steam sheath joint: G1/2″male thread |
Measure range | 300~2200mm; Customize other range |
Working temperature | 20~280ºC(borosilicate glass); -20~500ºC (Al-SI glass/mica glass) |
Working pressure | 0.6MPa, 2.5Mpa, 4.0MPa, 6.3MPa, 16MPa,32MPa |
Meter material | carbon steel, SS304 or SS316 |
Transmit color | nature color, or bi-color type(green for liquid, red for air) |
Ordinary globe valve or 1/4 opens or close valve | |
Lamp lighting | fluorescent lamp power supply AC36V |
Glass size | 80mm, 115mm, 140mm, 165mm, 190mm, 218mm, 260mm, 280mm, 290mm, 320mm, 340mm; |
Connection center to center adjustable distance | ±5mm |
2.Model selection
When open the packing, firstly check the substance, and tight the bolt again. And then according to the picture equip with the accessories.
3. Installation
- If the meter without light equipment, it can be installed at the light bright place.
- The flange and the sealing face can't be damaged for contaminated.
- If the measure range is very wide and must use serious meter to measure, their installing place should be separated without blind zone.
- When use the level gauge, water pressure should be check firstly, and the pressure the meter can bear is no more than 1.5 times of the maximum pressure. The test must conform to the pressure vessel safely requirement of the relative department.
- When install series TBS meter, the top and bottom needle valves must be closed. When operating, firstly open the top needle valve to its maximum degree and then open the bottom needle valve slowly to lead the fluid into the meter. And then loose the vent valve to vent gas. After vent out the gas then tight the vent valve immediately. When turning the needle valves.
4. Ordering instructions
- Model No. and specifications;
- Measuring ranges;
- Working pressure and temperature
- Material
- Whether have special requirements;
- Whether need to supply the accessories such as flange, nut, bolt, valves and packing washer